What is DSIP?
DSIP is a synthetic nonapeptide supplied as lyophilised powder for laboratory research. It is a linear, unmodified peptide with free amino and carboxyl termini, neither acetylated nor amidated.
DSIP structure and sequence
The sequence is Trp-Ala-Gly-Gly-Asp-Ala-Ser-Gly-Glu (WAGGDASGE), CAS 62568-57-4, molecular formula C35H48N10O15, molecular weight approximately 848.81 g/mol.
The backbone is glycine rich and largely uncharged, punctuated by acidic residues at positions 5 and 9. The single tryptophan at the N terminus provides a UV active chromophore, which is useful for spectroscopic detection during analysis.
A note on the compound name
Delta sleep inducing peptide is the historical designation given when the sequence was first isolated and characterised from rabbit cerebral venous blood in the 1970s. It is retained in the literature as the compound’s common identifier. It is a name, not a description of activity, and nothing on this page should be read as a claim of any effect.
An unusually well documented isolation
DSIP is one of the older sequences in the catalogue, isolated and sequenced in the 1970s, and the original amino acid analysis, sequence determination and synthesis were published together. That makes its identity unusually well established for a compound of its age, which is part of why it remains useful as a reference peptide.
Analysis and certification
Each lot of DSIP is analysed by an independent laboratory using RP-HPLC with LC-MS identity confirmation before it is released for sale. The certificate of analysis is published against the lot number rather than the product page, so the document you read is the document for the vial you receive.
Research use only
NH Peptides supplies DSIP as an analytical reference standard for laboratory research. It is not supplied for any use in humans or animals, and no information on this page describes or implies any such use.
Purity specification for DSIP
Lots are released against a ≥99% purity specification, determined by RP-HPLC peak area. The figure for the lot you receive is stated on its certificate of analysis and may differ from the specification.
A specification is a release threshold, not a description of every lot. Where a measured figure and the specification differ, the certificate is the record that applies to your material. Analytical figures relate to the lot they are published against and carry no implication of suitability for any purpose beyond laboratory research.
| Compound |
DSIP |
| Also known as |
Delta sleep inducing peptide, emideltide |
| Class |
Synthetic nonapeptide |
| Amino acids |
9 |
| Sequence |
Trp-Ala-Gly-Gly-Asp-Ala-Ser-Gly-Glu |
| CAS number |
62568-57-4 |
| Molecular formula |
C35H48N10O15 |
| Molecular weight |
Approximately 848.81 g/mol |
| Termini |
Free N and C termini, not acetylated or amidated |
| Appearance |
White to off white lyophilised powder |
| Purity specification |
≥99% |
| Identity method |
LC-MS |
| Purity method |
RP-HPLC |
| Labelled quantity |
10mg |
Characterisation. Original amino acid analysis, sequence determination and synthesis: PubMed 568769. Values for the lot supplied are stated on its certificate of analysis.
How DSIP is tested
Two separate analyses are carried out on every lot before it is released, and both appear on the certificate.
RP-HPLC, for purity
Reversed phase high performance liquid chromatography separates the material by hydrophobicity. The main peak is integrated against the total peak area to give the purity figure. This is what the ≥99% specification refers to, and it is a measure of how much of the material is the intended compound rather than related substances, residual reagents or truncated sequences.
LC-MS, for identity
Liquid chromatography coupled to mass spectrometry confirms that the material eluting in the main peak has the expected mass. Purity alone does not establish identity: a lot can be 99% pure and still be the wrong compound. The two analyses answer different questions and both are needed.
What arrives with the order
- The vial, labelled with compound, labelled quantity and lot number
- A dispatch note listing the lot numbers supplied
- A storage and handling sheet
- The certificate of analysis for the lot, published against the lot number
If any of these is missing, or if the lot number on the vial does not match the certificate, contact us before using the material.
Storing DSIP
Lyophilised material is shipped under cold chain and should be returned to freezer storage on arrival. Store the sealed vial dry at −20°C or below, protected from light and moisture.
Preparing DSIP stock solutions
Prepare stock solutions in sterile water or an appropriate aqueous buffer for analytical work, at a concentration suited to your assay. Confirm solubility against the certificate of analysis before preparing stocks.
Peptide solutions are less stable than lyophilised powder. Prepare close to the point of use, hold at 2–8°C for short periods only, and avoid repeated freeze and thaw cycles.
Handling and disposal
Assess the hazards of this material before handling and use appropriate controls and protective equipment. It has not been characterised toxicologically and should be treated as potentially hazardous.
Dispose of unused material, vials and packaging lawfully and in line with your institution's waste procedures. Anyone handling the material must be trained and competent to do so.
On receipt
Check the parcel before putting the material away. Three things are worth two minutes:
- Packaging integrity. Confirm the vial is intact, the seal is unbroken and the insulated packaging has not failed in transit.
- Lot number. Check the number on the vial label against the certificate of analysis and against the dispatch note. All three should agree.
- Return to storage. Move the material into its stated storage conditions promptly rather than leaving it at ambient temperature.
If anything does not match, or the packaging has clearly failed, contact us before using the material. Problems visible on arrival should be reported within 7 days so a carrier claim remains possible.
Record keeping
Record the lot number in your notes at the point of first use, alongside the date the vial was opened and the concentration of any stock solution prepared. Certificates are published against the lot number rather than the product, so the lot number is the only reliable link between your results and the analytical data for the material that produced them.
That link matters later. If a question arises about a result months after the work, the lot number is what makes the material traceable and the work auditable.